US Amps AX User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
9
Wiring Instructions for AX-TU600C/1000/2000
Negative 12V to Vehicle Ground
(Use minimum 8-gauge Wire)
F
U
S
E
Vehicle Battery
11 to 15 volts DC
+
Vehicle Ground
Source Unit
Positive 12V Remote Turn-on
AX-TU600C
165W X 2 @ 4Ω
300W X 2 @ 2Ω
AX-1000
300W X 2 @ 4Ω
500W X 2 @ 2Ω
AX-2000
600W X 2 @ 4Ω
1000W X 2 @ 2Ω
Power Output
Bridged Output
AX-TU600C
600W X 1 @ 4Ω
AX-1000
1000W X 1 @ 4Ω
AX-2000
2000W X 1 @ 4Ω
+
+
WARNING: NEVER use ground-loop isolation
on the input of your U.S.Amp! It doesn’t need it!
+
+
+
+
LEFT
[—]
LEFT
[+]
RIGHT
[—]
RIGHT
[+]
+
+
+
+
GND
REM
12V
POS
Positive 12V to Vehicle Battery
(Use minimum 4-gauge Wire)
AX-TU600C:
AX-1000:
AX-2000:
60A
100A
200A
Fuse Rating